Cape Vincent to seek input on proposed restrictions for wind farms; hopes to adopt updated zoning law in August 

Credit:  By JAEGUN LEE, TIMES STAFF WRITER | www.ogd.com 24 June 2012 ~~

The town of Cape Vincent plans to adopt a new zoning law – which includes strict restrictions on wind farms – in August before the state makes amendments to Article X of the 2011 Power NY Act.

Two public hearings are scheduled. The first, hosted by the Zoning Law Revision Committee, will be at 6 p.m. June 27 at the Recreation Park on James Street.

The second one is the Town Council’s joint hearing for both the updated zoning law and the comprehensive plan, which is tentatively set for July 21, same location.

Cape Vincent officials have discussed scheduling a special meeting Aug. 1 to vote on adopting the proposed changes.

In the draft proposal, Cape Vincent makes it clear that solar, not wind, energy is “the town’s preferred alternative energy technology.”

The town is the proposed site of BP Wind Energy’s $300 million Cape Vincent Wind Farm project, which would produce approximately 200 megawatts of electricity. Article X regulates the siting of electrical energy-generation facilities with more than 25 megawatts.

“These structures will have far greater impact on rural, scenic vistas and view sheds than existing telecommunication towers, not only because of their greater height and numbers, but also because of their movement, which attracts viewer attention,” the draft law states. “Turbine height, movement and the numbers of turbines also pose a risk to avian species moving along the town’s coastal migratory corridor.”

Because industrial commercial turbine operations “have health and safety impacts on people,” Cape Vincent’s draft law reads, these concerns “must be addressed with adequate setbacks for ice throw, rotor failure, shadow flicker, and noise.”

Under the new draft zoning law, setbacks for wind turbines will vary depending on the height and location of the structure. Noise limits for turbines will vary depending on the time of the day.

Proposed setbacks for large commercial turbines are:

■ Six times the total height of the proposed structure from the nearest residence, the nearest project boundary line, boundaries of adjacent towns and any road.

■ Two miles from Lake Ontario and St. Lawrence River waterfronts.

■ 1.25 miles from boundaries of the village of Cape Vincent and hamlets of Rosiere, Millens Bay and St. Lawrence Corners; from Route 12E; Seaway Trail; National Scenic Byways and schools.

A-weighted, audible spectrum, noise limits proposed are:

■ Daytime (7 a.m. to 7 p.m.), 45 dB.

■ Evening (7 to 10 p.m.), 40 dB.

■ Nighttime (10 p.m. to 7 a.m.), 35 dB

Under the proposal, the C-weighted, or low-frequency, wind turbine noise limit will be 18 dB over the A-weighted limit and both levels must be measured 1.5 miles from a commercial turbine.

Also, if operation noise contains a “steady pure tone” – such as a whine, screech or hum – the upper noise limit is to be reduced by 5 dB; for “impulsive noises,” the limit is reduced by 7 dB; and for “highly impulsive noise” by 12 dB.

Cape Vincent’s proposed restriction on “big wind” does not end there.

The new law would require all power transmission lines from the tower to any building or other structure to be underground.

Also, Cape Vincent wants to have wind farm developers “reduce the visual impact” of wind turbines by having the structures finished in “a single, non-reflective matte finished color or a camouflage scheme.”

Furthermore, Cape Vincent would require developers to address complaints within 24 hours and provide proof of “continuous liability insurance” of $5 million per occurrence with a total policy minimum of $20 million per year.

Developers would be required to conduct several impact studies, including shadow flicker, visual and noise impacts, wildlife impact, electromagnetic interference and stray voltage.

Developers would have to conduct additional studies and provide plans for cultural, historical and archaeological resources; operation and maintenance, and fire protection/emergency response.

After taking over Acciona Wind Energy USA’s proposed St. Lawrence Wind Farm project in Cape Vincent, BP in February hinted it would submit an application to the state’s siting board under Article X if the local government adopts a strict wind law.

Source:  By JAEGUN LEE, TIMES STAFF WRITER | www.ogd.com 24 June 2012

This article is the work of the source indicated. Any opinions expressed in it are not necessarily those of National Wind Watch.

The copyright of this article resides with the author or publisher indicated. As part of its noncommercial educational effort to present the environmental, social, scientific, and economic issues of large-scale wind power development to a global audience seeking such information, National Wind Watch endeavors to observe “fair use” as provided for in section 107 of U.S. Copyright Law and similar “fair dealing” provisions of the copyright laws of other nations. Send requests to excerpt, general inquiries, and comments via e-mail.

Wind Watch relies entirely
on User Funding
   Donate via Paypal
(via Paypal)
Donate via Stripe
(via Stripe)

Share:

e-mail X FB LI TG TG Share


News Watch Home

Get the Facts
CONTACT DONATE PRIVACY ABOUT SEARCH
© National Wind Watch, Inc.
Use of copyrighted material adheres to Fair Use.
"Wind Watch" is a registered trademark.

 Follow:

Wind Watch on X Wind Watch on Facebook

Wind Watch on Linked In Wind Watch on Mastodon